Cargo lights ignited cargo fire onboard bulker: Case study

Fire on the shipIn a recently published casebook featuring four case studies, The Swedish Club has shared information about an incident where floodlights caused a cargo fire on a bulk carrier.

A bulker had loaded sugar beet pellets in all three cargo holds with the operation taking 27 hours. When loading was completed the ventilation hatches and all other access points to the cargo holds were secured. In cargo hold 1 there were two metres of space between the cargo and the cargo hatch. In cargo holds 2 and 3 the cargo was almost up to the hatch coaming.

Two days into the voyage the crew noticed smoke coming from cargo hold 2. Hot spots were discovered in hold 2 on the transverse hatch coaming, both forward and aft on the portside, and an additional hot spot was also discovered on hold 3 on the transverse hatch coaming, on the portside aft.All hot spots were located adjacent to recesses in the coamings for the cargo holds’ floodlights. The crew isolated the electrical power to the floodlights. Because of the increased temperature of the hot spots in hold 2, the Master released CO2 into the hold.

The CO2 did not extinguish the fire but reduced its severity for a while. When the vessel arrived at the discharge port the cargo hatches were opened, and flames broke out from hold 2. At the same time a plume of smoke escaped from hold 3. The top layer of cargo in hold 2 had been burned.

About 4 metres below the cargo surface the cargo was in good condition. It was discovered that the cargo in hold 3 had been damaged by condensation and tainted by smoke. There were clear burn marks around the floodlights and distinct burn marks by the coaming at the same locations where the hot spots had been discovered.

The floodlights were situated 1 metre below the cargo surface in holds 2 and 3 and there was black, burned cargo covering the floodlights. There were two floodlights fitted in cargo hold 1, port and starboard and four floodlights fitted in both cargo holds 2 and 3.

All the floodlights were installed in recesses in the hatch coaming. The floodlights were protected by round bars preventing crane hooks, grabs etc from hitting them, but these bars do not prevent cargo like sugar beet pellets from covering the lights. The floodlights were controlled from the bridge on a panel with four key-switches. These switches were marked 1, 2, 3 and 4 respectively. No drawings or legends were attached clarifying which areas these key-switches served.

Lessons learned

– The subsequent investigation revealed that the cargo floodlights were not connected according to the approved ‘as built’ circuit diagrams delivered with the vessel. It was not clear on board which lights were controlled by which keyswitch.
– The fire was caused because a number of cargo lights were operating while cargo covered them, so the lights ignited the cargo. There was a lack of information on board about how the light circuits were connected and how the light system should be operated. There was also a lack of records concerning use of the lights.
– Many bulk carrier/general cargo holds have fixed cargo lights. Halogen-type lights can easily ignite combustible cargoes such as grain, animal feed, wood chips, pulp and paper if they are too close to the light.
– Cargo lights in holds need to be properly isolated before cargo is loaded. This is best done by removing fuses or other physical links in the electrical circuits so that the lights cannot be switched on by mistake. In container ships the lights need to be properly placed so that they do not overheat cargo or other combustibles and thus cause damage or fire. Lights in car carriers and ferries are usually fluorescent, which are unlikely to cause ignition. Nonetheless it makes sense to leave lights switched off when they are not needed, particularly in cargo areas where combustibles are present.

Download the full casebook: Swedish Club Casebook

Instagram Posts from the IIMS @iimsmarine

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Strictly Necessary Cookies

Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.

Show details
Performance & Marketing Cookies

This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages. This also helps us optimise our marketing campaigns. User data sent to Google Analytics may be used for ad personalization and measurement of our ad campaigns. Keeping this cookie enabled helps us to improve our website.

Show details